CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.
2012-02-03T20:55:01.453
2025-04-11T00:51:21.963
Deferred
CVSSv2: 5.0 (MEDIUM)
AV:N/AC:L/Au:N/C:N/I:P/A:N
10.0
2.9
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Application | siemens | wincc_flexible | 2004 | Yes |
Application | siemens | wincc_flexible | 2005 | Yes |
Application | siemens | wincc_flexible | 2007 | Yes |
Application | siemens | wincc_flexible | 2008 | Yes |
Application | siemens | wincc_flexible | 2008 | Yes |
Application | siemens | wincc_flexible | 2008 | Yes |
Application | siemens | wincc | ≤ v11 | Yes |
Application | siemens | wincc | v11 | Yes |
Application | siemens | wincc | v11 | Yes |
Application | siemens | simatic_hmi_panels | comfort_panels | Yes |
Application | siemens | simatic_hmi_panels | mobile_panels | Yes |
Application | siemens | simatic_hmi_panels | mp | Yes |
Application | siemens | simatic_hmi_panels | op | Yes |
Application | siemens | simatic_hmi_panels | tp | Yes |
Application | siemens | wincc_runtime_advanced | v11 | Yes |
Application | siemens | wincc_flexible_runtime | * | Yes |