miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
CVE-2011-4879 is a security vulnerability that . Impacting 5 products from siemens, from siemens, from siemens and 2 others, organizations running these solutions should prioritize assessment and patching.
Documented in 2012, this vulnerability occurred amid the cloud computing expansion era, where traditional network perimeter security models were being reevaluated. Organizations were transitioning from isolated infrastructure to interconnected systems, creating new attack surfaces that vulnerabilities like this could exploit.
2012-02-03T20:55:02.077
2025-04-11T00:51:21.963
Deferred
CVSSv2: 8.5 (HIGH)
AV:N/AC:L/Au:N/C:P/I:N/A:C
10.0
7.8
| Type | Vendor | Product | Version/Range | Vulnerable? |
|---|---|---|---|---|
| Application | siemens | wincc_flexible | 2004 | Yes |
| Application | siemens | wincc_flexible | 2005 | Yes |
| Application | siemens | wincc_flexible | 2007 | Yes |
| Application | siemens | wincc_flexible | 2008 | Yes |
| Application | siemens | wincc_flexible | 2008 | Yes |
| Application | siemens | wincc_flexible | 2008 | Yes |
| Application | siemens | wincc | ≤ v11 | Yes |
| Application | siemens | wincc | v11 | Yes |
| Application | siemens | wincc | v11 | Yes |
| Application | siemens | simatic_hmi_panels | comfort_panels | Yes |
| Application | siemens | simatic_hmi_panels | mobile_panels | Yes |
| Application | siemens | simatic_hmi_panels | mp | Yes |
| Application | siemens | simatic_hmi_panels | op | Yes |
| Application | siemens | simatic_hmi_panels | tp | Yes |
| Application | siemens | wincc_runtime_advanced | v11 | Yes |
| Application | siemens | wincc_flexible_runtime | * | Yes |
SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For siemens's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.