Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2012-2282


EMC Celerra Network Server 6.x before 6.0.61.0, VNX 7.x before 7.0.53.2, and VNXe 2.0 and 2.1 before 2.1.3.19077 (aka MR1 SP3.2) and 2.2 before 2.2.0.19078 (aka MR2 SP0.2) do not properly implement NFS access control, which allows remote authenticated users to read or modify files via a (1) NFSv2, (2) NFSv3, or (3) NFSv4 request.


Published

2012-07-16T20:55:00.830

Last Modified

2025-04-11T00:51:21.963

Status

Deferred

Source

[email protected]

Severity

CVSSv2: 6.5 (MEDIUM)

CVSSv2 Vector

AV:N/AC:L/Au:S/C:P/I:P/A:P

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: SINGLE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: PARTIAL
  • Availability Impact: PARTIAL
Exploitability Score

8.0

Impact Score

6.4

Weaknesses
  • Type: Primary
    CWE-264

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application emc celerra_network_server 6.0.36.4 Yes
Application emc celerra_network_server 6.0.60.2 Yes
Application emc vnx 7.0.12.0 Yes
Application emc vnx 7.0.53.1 Yes
Application emc vnxe 2.0 Yes
Application emc vnxe 2.0 Yes
Application emc vnxe 2.0 Yes
Application emc vnxe 2.0 Yes
Application emc vnxe mr1 Yes
Application emc vnxe mr1 Yes
Application emc vnxe mr1 Yes
Application emc vnxe mr1 Yes
Application emc vnxe mr2 Yes

References