Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
2019-03-26T17:29:00.310
2024-11-21T01:52:24.090
Modified
CVSSv3.0: 7.5 (HIGH)
AV:N/AC:L/Au:N/C:N/I:N/A:C
10.0
6.9
| Type | Vendor | Product | Version/Range | Vulnerable? |
|---|---|---|---|---|
| Application | rockwellautomation | rslinx_enterprise | 5.10.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.10.01 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.20.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.21.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.30.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.40.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.50.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.51.00 | Yes |
| Application | rockwellautomation | rslinx_enterprise | 5.60.00 | Yes |