Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.


Published

2013-08-06T20:55:05.287

Last Modified

2025-04-11T00:51:21.963

Status

Deferred

Source

[email protected]

Severity

CVSSv2: 9.3 (HIGH)

CVSSv2 Vector

AV:N/AC:M/Au:N/C:C/I:C/A:C

  • Access Vector: NETWORK
  • Access Complexity: MEDIUM
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

8.6

Impact Score

10.0

Weaknesses
  • Type: Primary
    CWE-22

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application ni labview ≤ 2012 Yes
Application ni labwindows ≤ 2012 Yes
Application ni measurementstudio ≤ 2013 Yes
Application ni teststand ≤ 2012 Yes
Application abb datamanager 1.0.0 Yes
Application abb datamanager 6.3.6 Yes