Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2013-5022


Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.


Published

2013-08-06T20:55:05.413

Last Modified

2025-04-11T00:51:21.963

Status

Deferred

Source

[email protected]

Severity

CVSSv2: 10.0 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

10.0

Weaknesses
  • Type: Primary
    CWE-22

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application ni labview ≤ 2012 Yes
Application ni labwindows ≤ 2012 Yes
Application ni measurementstudio ≤ 2013 Yes
Application ni teststand ≤ 2012 Yes

References