CVE-2013-5944


The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.


Published

2013-10-03T11:04:43.773

Last Modified

2025-04-11T00:51:21.963

Status

Deferred

Source

[email protected]

Severity

CVSSv2: 10.0 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

10.0

Weaknesses
  • Type: Primary
    CWE-287

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System siemens scalance_x-200_series_firmware ≤ 4.4 Yes
Operating System siemens scalance_x-200_series_firmware 4.3 Yes
Hardware siemens scalance_x-200 - Yes
Operating System siemens scalance_x-200_series_firmware ≤ 5.0.1 Yes
Hardware siemens scalance_x-200irt - Yes