Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
CVE-2015-3963 is a security vulnerability that . Impacting 14 products from windriver, from schneider-electric, from schneider-electric and 11 others, organizations running these solutions should prioritize assessment and patching.
First disclosed in 2015, this vulnerability was reported during a period defined by widespread IoT adoption challenges, mobile security concerns, and the emergence of advanced persistent threat (APT) techniques. Contemporary mitigation strategies focused on secure development practices and third-party component vetting.
2015-08-04T01:59:07.357
2025-04-12T10:46:40.837
Deferred
CVSSv2: 5.8 (MEDIUM)
AV:N/AC:M/Au:N/C:N/I:P/A:P
8.6
4.9
| Type | Vendor | Product | Version/Range | Vulnerable? |
|---|---|---|---|---|
| Operating System | windriver | vxworks | ≤ 6.6 | Yes |
| Operating System | windriver | vxworks | < 6.7.1.1 | Yes |
| Operating System | windriver | vxworks | < 6.8.3 | Yes |
| Operating System | windriver | vxworks | < 6.9.4.4 | Yes |
| Operating System | windriver | vxworks | 6.6.3 | Yes |
| Operating System | windriver | vxworks | 6.6.4 | Yes |
| Operating System | windriver | vxworks | 6.6.4.1 | Yes |
| Operating System | windriver | vxworks | 7.0 | Yes |
| Hardware | schneider-electric | sage_1210 | - | No |
| Hardware | schneider-electric | sage_1230 | - | No |
| Hardware | schneider-electric | sage_1250 | - | No |
| Hardware | schneider-electric | sage_1310 | - | No |
| Hardware | schneider-electric | sage_1330 | - | No |
| Hardware | schneider-electric | sage_1350 | - | No |
| Hardware | schneider-electric | sage_1410 | - | No |
| Hardware | schneider-electric | sage_1430 | - | No |
| Hardware | schneider-electric | sage_1450 | - | No |
| Hardware | schneider-electric | sage_2200 | - | No |
| Hardware | schneider-electric | sage_2400 | - | No |
| Hardware | schneider-electric | sage_3030 | - | No |
| Hardware | schneider-electric | sage_3030_magnum | - | No |
SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For windriver's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.