A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28). Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these variables could reduce the availability or cause a denial-of-service.
2016-11-18T21:59:02.033
2025-04-12T10:46:40.837
Deferred
CVSSv3.1: 7.5 (HIGH)
AV:N/AC:M/Au:S/C:N/I:N/A:P
6.8
2.9
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Operating System | siemens | simatic_cp_1543-1_firmware | < 2.0.28 | Yes |
Hardware | siemens | simatic_cp_1543-1 | - | No |
Operating System | siemens | siplus_net_cp_1543-1_firmware | < 2.0.28 | Yes |
Hardware | siemens | siplus_net_cp_1543-1 | - | No |