Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2017-6015


Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.


Published

2018-05-11T13:29:00.297

Last Modified

2024-11-21T03:28:54.360

Status

Modified

Source

[email protected]

Severity

CVSSv3.0: 7.8 (HIGH)

CVSSv2 Vector

AV:L/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: LOCAL
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

3.9

Impact Score

10.0

Weaknesses
  • Type: Secondary
    CWE-428
  • Type: Primary
    CWE-74

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application rockwellautomation factorytalk_activation ≤ 4.00.02 Yes

References