Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2017-6017


A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.


Security Impact Summary

This vulnerability carries a HIGH severity rating with a CVSS v3.1 score of 7.5, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts and availability (service disruption) for affected systems. Impacting 30 products from schneider-electric, from schneider-electric, from schneider-electric and 27 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

First disclosed in 2017, this vulnerability was reported during a period defined by widespread IoT adoption challenges, mobile security concerns, and the emergence of advanced persistent threat (APT) techniques. Contemporary mitigation strategies focused on secure development practices and third-party component vetting.


Published

2017-06-30T03:29:00.233

Last Modified

2025-04-20T01:37:25.860

Status

Deferred

Source

[email protected]

Severity

CVSSv3.0: 7.5 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:N/I:N/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: NONE
  • Integrity Impact: NONE
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

6.9

Weaknesses
  • Type: Secondary
    CWE-400
  • Type: Primary
    CWE-400

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System schneider-electric bmxnoc0401_firmware 2.8 Yes
Hardware schneider-electric bmxnoc0401 - No
Operating System schneider-electric bmxnoe0100_firmware 2.8 Yes
Hardware schneider-electric bmxnoe0100 - No
Operating System schneider-electric bmxnoe0110_firmware 2.8 Yes
Hardware schneider-electric bmxnoe0110 - No
Operating System schneider-electric bmxnoe0110h_firmware 2.8 Yes
Hardware schneider-electric bmxnoe0110h - No
Operating System schneider-electric bmxnor0200h_firmware 2.8 Yes
Hardware schneider-electric bmxnor0200h - No
Operating System schneider-electric modicon_m340_bmxp341000_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp341000 - No
Operating System schneider-electric modicon_m340_bmxp342000_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp342000 - No
Operating System schneider-electric modicon_m340_bmxp3420102_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp3420102 - No
Operating System schneider-electric modicon_m340_bmxp3420102cl_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp3420102cl - No
Operating System schneider-electric modicon_m340_bmxp342020_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp342020 - No
Operating System schneider-electric modicon_m340_bmxp342020h_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp342020h - No
Operating System schneider-electric modicon_m340_bmxp342030_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp342030 - No
Operating System schneider-electric modicon_m340_bmxp3420302_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp3420302 - No
Operating System schneider-electric modicon_m340_bmxp3420302h_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp3420302h - No
Operating System schneider-electric modicon_m340_bmxp342030h_firmware 2.8 Yes
Hardware schneider-electric modicon_m340_bmxp342030h - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For schneider-electric's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.