An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub_1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub_15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x0008F598 which calls the "mailLoginTest" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.


Security Impact Summary

This vulnerability carries a CRITICAL severity rating with a CVSS v3.1 score of 9.8, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 2 products from dlink, from dlink organizations running these solutions should prioritize assessment and patching.

Historical Context

First disclosed in 2019, this vulnerability was reported during a period defined by widespread IoT adoption challenges, mobile security concerns, and the emergence of advanced persistent threat (APT) techniques. Contemporary mitigation strategies focused on secure development practices and third-party component vetting.


Published

2019-07-02T19:15:10.413

Last Modified

2024-11-21T03:33:58.043

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 9.8 (CRITICAL)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

10.0

Weaknesses
  • Type: Primary
    CWE-77

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System dlink dcs-1130_firmware - Yes
Hardware dlink dcs-1130 - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For dlink's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.