After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3.
2018-07-11T18:29:00.293
2024-11-21T03:37:23.333
Modified
CVSSv3.0: 4.7 (MEDIUM)
AV:N/AC:L/Au:N/C:N/I:P/A:N
10.0
2.9
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Operating System | juniper | junos | 15.1 | Yes |
Operating System | juniper | junos | 15.1 | Yes |
Operating System | juniper | junos | 15.1 | Yes |
Operating System | juniper | junos | 15.1x8 | Yes |