An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
2018-10-30T18:29:00.580
2025-03-20T21:03:53.180
Analyzed
CVSSv3.1: 9.8 (CRITICAL)
AV:N/AC:L/Au:N/C:C/I:C/A:C
10.0
10.0
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Operating System | tenda | ac7_firmware | ≤ 15.03.06.44_cn | Yes |
Hardware | tenda | ac7 | - | No |
Operating System | tenda | ac9_firmware | ≤ 15.03.05.19\(6318\)_cn | Yes |
Hardware | tenda | ac9 | - | No |
Operating System | tenda | ac10_firmware | ≤ 15.03.06.23_cn | Yes |
Hardware | tenda | ac10 | - | No |