A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
This vulnerability carries a HIGH severity rating with a CVSS v3.1 score of 7.8, requiring local system access to exploit with relatively low complexity though user interaction is required and does not require pre-existing privileges . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 11 products from siemens, from siemens, from siemens and 8 others, organizations running these solutions should prioritize assessment and patching.
First disclosed in 2018, this vulnerability was reported during a period defined by widespread IoT adoption challenges, mobile security concerns, and the emergence of advanced persistent threat (APT) techniques. Contemporary mitigation strategies focused on secure development practices and third-party component vetting.
2018-07-09T19:29:00.407
2026-06-17T01:59:10.887
Modified
CVSSv3.1: 7.8 (HIGH)
AV:N/AC:M/Au:N/C:C/I:C/A:C
8.6
10.0
| Type | Vendor | Product | Version/Range | Vulnerable? |
|---|---|---|---|---|
| Operating System | siemens | ec_61850_system_configurator_firmware | < 5.80 | Yes |
| Hardware | siemens | ec_61850_system_configurator | - | No |
| Operating System | siemens | sicam_pq_analyzer_firmware | < 3.11 | Yes |
| Hardware | siemens | sicam_pq_analyzer | - | No |
| Operating System | siemens | sicam_scc_firmware | - | Yes |
| Hardware | siemens | sicam_scc | - | No |
| Operating System | siemens | digsi_4_firmware | - | Yes |
| Hardware | siemens | digsi_4 | - | No |
| Operating System | siemens | digsi_5_firmware | < 7.80 | Yes |
| Hardware | siemens | digsi_5 | - | No |
| Application | siemens | sicam_pas\/pqs | < 8.11 | Yes |
SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For siemens's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.