A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code.


Security Impact Summary

This vulnerability carries a MEDIUM severity rating with a CVSS v3.1 score of 6.1, indicating it can be exploited remotely over the network with relatively low complexity though user interaction is required and does not require pre-existing privileges . The vulnerability impacts limited data confidentiality, limited integrity, for affected systems. Impacting 2 products from schneider-electric, from schneider-electric organizations running these solutions should prioritize assessment and patching.

Historical Context

First disclosed in 2018, this vulnerability was reported during a period defined by widespread IoT adoption challenges, mobile security concerns, and the emergence of advanced persistent threat (APT) techniques. Contemporary mitigation strategies focused on secure development practices and third-party component vetting.


Published

2018-08-29T20:29:00.437

Last Modified

2024-11-21T04:12:45.000

Status

Modified

Source

[email protected]

Severity

CVSSv3.0: 6.1 (MEDIUM)

CVSSv2 Vector

AV:N/AC:M/Au:N/C:N/I:P/A:N

  • Access Vector: NETWORK
  • Access Complexity: MEDIUM
  • Authentication: NONE
  • Confidentiality Impact: NONE
  • Integrity Impact: PARTIAL
  • Availability Impact: NONE
Exploitability Score

8.6

Impact Score

2.9

Weaknesses
  • Type: Primary
    CWE-79

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System schneider-electric powerlogic_pm5560_firmware < 2.5.4 Yes
Hardware schneider-electric powerlogic_pm5560 - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For schneider-electric's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.