Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2019-19292


A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.


Published

2020-03-10T20:15:19.243

Last Modified

2024-11-21T04:34:30.683

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 8.8 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:S/C:P/I:P/A:P

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: SINGLE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: PARTIAL
  • Availability Impact: PARTIAL
Exploitability Score

8.0

Impact Score

6.4

Weaknesses
  • Type: Primary
    CWE-89
  • Type: Secondary
    CWE-89

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application siemens sinvr_3_central_control_server * Yes
Application siemens sinvr_3_video_server * Yes

References