Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2020-12003


FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.


Published

2020-06-15T20:15:11.397

Last Modified

2024-11-21T04:59:05.733

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 7.5 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:P/I:N/A:N

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: NONE
  • Availability Impact: NONE
Exploitability Score

10.0

Impact Score

2.9

Weaknesses
  • Type: Secondary
    CWE-22
  • Type: Primary
    CWE-22

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application rockwellautomation factorytalk_linx 6.00 Yes
Application rockwellautomation factorytalk_linx 6.10 Yes
Application rockwellautomation factorytalk_linx 6.11 Yes
Application rockwellautomation rslinx_classic ≤ 4.11.00 Yes

References