Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2020-12017


GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.


Published

2020-06-02T19:15:11.403

Last Modified

2024-11-21T04:59:07.367

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 9.8 (CRITICAL)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:P/I:P/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: PARTIAL
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

8.5

Weaknesses
  • Type: Secondary
    CWE-306
  • Type: Primary
    CWE-306

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System ge rt430_firmware < 08a05 Yes
Hardware ge rt430 - No
Operating System ge rt431_firmware < 08a05 Yes
Hardware ge rt431 - No
Operating System ge rt434_firmware < 08a05 Yes
Hardware ge rt434 - No

References