Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2020-15369


Supportlink CLI in Brocade Fabric OS Versions v8.2.1 through v8.2.1d, and 8.2.2 versions before v8.2.2c does not obfuscate the password field, which could expose users’ credentials of the remote server. An authenticated user could obtain the exposed password credentials to gain access to the remote host.


Security Impact Summary

This vulnerability carries a HIGH severity rating with a CVSS v3.1 score of 8.8, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction requiring only low-level privileges . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 1 product from broadcom organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2020, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2020-09-25T14:15:13.453

Last Modified

2024-11-21T05:05:25.783

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 8.8 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:S/C:P/I:N/A:N

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: SINGLE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: NONE
  • Availability Impact: NONE
Exploitability Score

8.0

Impact Score

2.9

Weaknesses
  • Type: Primary
    CWE-521

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System broadcom fabric_operating_system 8.2.1 Yes
Operating System broadcom fabric_operating_system 8.2.1a Yes
Operating System broadcom fabric_operating_system 8.2.1b Yes
Operating System broadcom fabric_operating_system 8.2.1c Yes
Operating System broadcom fabric_operating_system 8.2.1d Yes
Operating System broadcom fabric_operating_system 8.2.2 Yes
Operating System broadcom fabric_operating_system 8.2.2a Yes
Operating System broadcom fabric_operating_system 8.2.2a1 Yes
Operating System broadcom fabric_operating_system 8.2.2b Yes

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For broadcom's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.