CVE-2020-15787


A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.


Published

2020-09-09T19:15:19.990

Last Modified

2024-11-21T05:06:10.817

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 9.8 (CRITICAL)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:P/I:N/A:N

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: NONE
  • Availability Impact: NONE
Exploitability Score

10.0

Impact Score

2.9

Weaknesses
  • Type: Primary
    CWE-305
  • Type: Secondary
    CWE-287

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System siemens simatic_hmi_united_comfort_panels_firmware * Yes
Hardware siemens simatic_hmi_united_comfort_panels - No

References