Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2020-7580


A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.


Security Impact Summary

This vulnerability carries a MEDIUM severity rating with a CVSS v3.1 score of 6.7, requiring local system access to exploit with relatively low complexity without requiring user interaction . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 17 products from siemens, from siemens, from siemens and 14 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2020, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2020-06-10T17:15:12.347

Last Modified

2024-11-21T05:37:24.840

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 6.7 (MEDIUM)

CVSSv2 Vector

AV:L/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: LOCAL
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

3.9

Impact Score

10.0

Weaknesses
  • Type: Secondary
    CWE-428
  • Type: Secondary
    CWE-428

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application siemens simatic_automatic_tool * Yes
Application siemens simatic_net_pc < 16 Yes
Application siemens simatic_net_pc 16 Yes
Application siemens simatic_net_pc 16 Yes
Application siemens simatic_pcs_7 * Yes
Application siemens simatic_pcs_neo * Yes
Application siemens simatic_prosave * Yes
Application siemens simatic_s7-1500_software_controller < 21.8 Yes
Application siemens simatic_step_7 < 5.6 Yes
Application siemens simatic_step_7 ≤ 16 Yes
Application siemens simatic_step_7 5.6 Yes
Application siemens simatic_step_7 5.6 Yes
Application siemens simatic_step_7 5.6 Yes
Application siemens simatic_step_7 5.6 Yes
Application siemens simatic_wincc < 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.4 Yes
Application siemens simatic_wincc 7.5 Yes
Application siemens simatic_wincc 7.5 Yes
Application siemens simatic_wincc 7.5 Yes
Application siemens simatic_wincc 7.5 Yes
Application siemens simatic_wincc_open_architecture 3.16 Yes
Application siemens simatic_wincc_open_architecture 3.17 Yes
Application siemens simatic_wincc_runtime_advanced * Yes
Application siemens simatic_wincc_runtime_professional ≤ 16 Yes
Application siemens sinamics_startdrive * Yes
Application siemens sinamics_starter_commissioning_tool * Yes
Application siemens sinec_network_management_system * Yes
Application siemens sinema_server * Yes
Application siemens sinumerik_one_virtual * Yes
Application siemens sinumerik_operate * Yes

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For siemens's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.