Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2021-20612


Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.


Security Impact Summary

This vulnerability carries a HIGH severity rating with a CVSS v3.1 score of 7.5, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts and availability (service disruption) for affected systems. Impacting 6 products from mitsubishielectric, from mitsubishielectric, from mitsubishielectric and 3 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2022, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2022-01-14T20:15:09.850

Last Modified

2024-11-21T05:46:52.860

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 7.5 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:N/I:N/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: NONE
  • Integrity Impact: NONE
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

6.9

Weaknesses
  • Type: Primary
    NVD-CWE-Other

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System mitsubishielectric fx3u-enet_firmware ≤ 1.14 Yes
Hardware mitsubishielectric fx3u-enet - No
Operating System mitsubishielectric fx3u-enet-l_firmware ≤ 1.14 Yes
Hardware mitsubishielectric fx3u-enet-l - No
Operating System mitsubishielectric fx3u-enet-p502_firmware ≤ 1.14 Yes
Hardware mitsubishielectric fx3u-enet-p502 - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For mitsubishielectric's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.