Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2021-22729


A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.


Published

2021-07-21T15:15:14.753

Last Modified

2024-11-21T05:50:32.800

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 9.8 (CRITICAL)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

10.0

Impact Score

10.0

Weaknesses
  • Type: Secondary
    CWE-259

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System schneider-electric evlink_city_evc1s22p4_firmware < r8_v3.4.0.1 Yes
Hardware schneider-electric evlink_city_evc1s22p4 - No
Operating System schneider-electric evlink_city_evc1s7p4_firmware < r8_v3.4.0.1 Yes
Hardware schneider-electric evlink_city_evc1s7p4 - No
Operating System schneider-electric evlink_parking_evw2_firmware < r8_v3.4.0.1 Yes
Hardware schneider-electric evlink_parking_evw2 - No
Operating System schneider-electric evlink_parking_evf2_firmware < r8_v3.4.0.1 Yes
Hardware schneider-electric evlink_parking_evf2 - No
Operating System schneider-electric evlink_parking_ev.2_firmware < r8_v3.4.0.1 Yes
Hardware schneider-electric evlink_parking_ev.2 - No
Operating System schneider-electric evlink_smart_wallbox_evb1a_firmware < r8_v3.4.0.1 Yes
Hardware schneider-electric evlink_smart_wallbox_evb1a - No

References