A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.
2021-03-15T17:15:22.127
2024-11-21T05:55:16.667
Modified
CVSSv3.1: 7.5 (HIGH)
AV:N/AC:L/Au:N/C:N/I:N/A:P
10.0
2.9
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Operating System | siemens | ruggedcom_rm1224_firmware | 6.3 | Yes |
Hardware | siemens | ruggedcom_rm1224 | - | No |
Operating System | siemens | scalance_m-800_firmware | 6.3 | Yes |
Hardware | siemens | scalance_m-800 | - | No |
Operating System | siemens | scalance_s615_firmware | 6.3 | Yes |
Hardware | siemens | scalance_s615 | - | No |
Operating System | siemens | scalance_sc-600_firmware | < 2.1.3 | Yes |
Hardware | siemens | scalance_sc-600 | - | No |