Philips Gemini PET/CT family software stores sensitive information in a removable media device that does not have built-in access control.


Security Impact Summary

This vulnerability carries a LOW severity rating with a CVSS v3.1 score of 2.4, with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts limited data confidentiality, for affected systems. Impacting 22 products from phillips, from phillips, from phillips and 19 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2022, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2022-03-23T20:15:08.643

Last Modified

2024-11-21T05:58:01.547

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 2.4 (LOW)

CVSSv2 Vector

AV:L/AC:L/Au:N/C:P/I:N/A:N

  • Access Vector: LOCAL
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: NONE
  • Availability Impact: NONE
Exploitability Score

3.9

Impact Score

2.9

Weaknesses
  • Type: Secondary
    CWE-921
  • Type: Primary
    CWE-922

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System phillips gemini_882300_firmware - Yes
Hardware phillips gemini_882300 - No
Operating System phillips gemini_882160_firmware - Yes
Hardware phillips gemini_882160 - No
Operating System phillips gemini_882400_firmware - Yes
Hardware phillips gemini_882400 - No
Operating System phillips gemini_882390_firmware - Yes
Hardware phillips gemini_882390 - No
Operating System phillips gemini_882410_firmware - Yes
Hardware phillips gemini_882410 - No
Operating System phillips gemini_882412_firmware - Yes
Hardware phillips gemini_882412 - No
Operating System phillips gemini_882473_firmware - Yes
Hardware phillips gemini_882473 - No
Operating System phillips gemini_882470_firmware - Yes
Hardware phillips gemini_882470 - No
Operating System phillips gemini_882471_firmware - Yes
Hardware phillips gemini_882471 - No
Operating System phillips gemini_882476_firmware - Yes
Hardware phillips gemini_882476 - No
Operating System phillips truflight_882438_firmware - Yes
Hardware phillips truflight_882438 - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For phillips's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.