A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
2022-02-09T23:15:19.197
2024-11-21T06:47:29.110
Modified
CVSSv3.1: 7.4 (HIGH)
AV:N/AC:M/Au:N/C:N/I:P/A:N
8.6
2.9
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Operating System | schneider-electric | hmibscea53d1edb_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1edb | - | No |
Operating System | schneider-electric | hmibscea53d1eds_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1eds | - | No |
Operating System | schneider-electric | hmibscea53d1edm_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1edm | - | No |
Operating System | schneider-electric | hmibscea53d1edl_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1edl | - | No |
Operating System | schneider-electric | hmibscea53d1ess_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1ess | - | No |
Operating System | schneider-electric | hmibscea53d1esm_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1esm | - | No |
Operating System | schneider-electric | hmibscea53d1eml_firmware | < 4.0.0.13 | Yes |
Hardware | schneider-electric | hmibscea53d1eml | - | No |