Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2022-22813


A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.


Security Impact Summary

This vulnerability carries a CRITICAL severity rating with a CVSS v3.1 score of 9.8, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 66 products from schneider-electric, from schneider-electric, from schneider-electric and 63 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2022, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2022-02-09T23:15:19.480

Last Modified

2024-11-21T06:47:29.877

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 9.8 (CRITICAL)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:P/I:P/A:P

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: PARTIAL
  • Availability Impact: PARTIAL
Exploitability Score

10.0

Impact Score

6.4

Weaknesses
  • Type: Secondary
    CWE-798

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System schneider-electric easergy_p141_firmware - Yes
Hardware schneider-electric easergy_p141 - No
Operating System schneider-electric easergy_p142_firmware - Yes
Hardware schneider-electric easergy_p142 - No
Operating System schneider-electric easergy_p143_firmware - Yes
Hardware schneider-electric easergy_p143 - No
Operating System schneider-electric easergy_p145_firmware - Yes
Hardware schneider-electric easergy_p145 - No
Operating System schneider-electric easergy_p241_firmware - Yes
Hardware schneider-electric easergy_p241 - No
Operating System schneider-electric easergy_p242_firmware - Yes
Hardware schneider-electric easergy_p242 - No
Operating System schneider-electric easergy_p243_firmware - Yes
Hardware schneider-electric easergy_p243 - No
Operating System schneider-electric easergy_p342_firmware - Yes
Hardware schneider-electric easergy_p342 - No
Operating System schneider-electric easergy_p343_firmware - Yes
Hardware schneider-electric easergy_p343 - No
Operating System schneider-electric easergy_p344_firmware - Yes
Hardware schneider-electric easergy_p344 - No
Operating System schneider-electric easergy_p345_firmware - Yes
Hardware schneider-electric easergy_p345 - No
Operating System schneider-electric easergy_p441_firmware - Yes
Hardware schneider-electric easergy_p441 - No
Operating System schneider-electric easergy_p442_firmware - Yes
Hardware schneider-electric easergy_p442 - No
Operating System schneider-electric easergy_p443_firmware - Yes
Hardware schneider-electric easergy_p443 - No
Operating System schneider-electric easergy_p444_firmware - Yes
Hardware schneider-electric easergy_p444 - No
Operating System schneider-electric easergy_p445_firmware - Yes
Hardware schneider-electric easergy_p445 - No
Operating System schneider-electric easergy_p446_firmware - Yes
Hardware schneider-electric easergy_p446 - No
Operating System schneider-electric easergy_p541_firmware - Yes
Hardware schneider-electric easergy_p541 - No
Operating System schneider-electric easergy_p542_firmware - Yes
Hardware schneider-electric easergy_p542 - No
Operating System schneider-electric easergy_p543_firmware - Yes
Hardware schneider-electric easergy_p543 - No
Operating System schneider-electric easergy_p544_firmware - Yes
Hardware schneider-electric easergy_p544 - No
Operating System schneider-electric easergy_p545_firmware - Yes
Hardware schneider-electric easergy_p545 - No
Operating System schneider-electric easergy_p546_firmware - Yes
Hardware schneider-electric easergy_p546 - No
Operating System schneider-electric easergy_p642_firmware - Yes
Hardware schneider-electric easergy_p642 - No
Operating System schneider-electric easergy_p643_firmware - Yes
Hardware schneider-electric easergy_p643 - No
Operating System schneider-electric easergy_p645_firmware - Yes
Hardware schneider-electric easergy_p645 - No
Operating System schneider-electric easergy_p741_firmware - Yes
Hardware schneider-electric easergy_p741 - No
Operating System schneider-electric easergy_p742_firmware - Yes
Hardware schneider-electric easergy_p742 - No
Operating System schneider-electric easergy_p743_firmware - Yes
Hardware schneider-electric easergy_p743 - No
Operating System schneider-electric easergy_p746_firmware - Yes
Hardware schneider-electric easergy_p746 - No
Operating System schneider-electric easergy_p341_firmware - Yes
Hardware schneider-electric easergy_p341 - No
Operating System schneider-electric easergy_p841_firmware - Yes
Hardware schneider-electric easergy_p841 - No
Operating System schneider-electric easergy_p849_firmware - Yes
Hardware schneider-electric easergy_p849 - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For schneider-electric's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.