Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2022-24285


Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.


Published

2022-03-10T17:46:02.813

Last Modified

2024-11-21T06:50:05.380

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 7.8 (HIGH)

CVSSv2 Vector

AV:L/AC:L/Au:N/C:C/I:C/A:C

  • Access Vector: LOCAL
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

3.9

Impact Score

10.0

Weaknesses
  • Type: Primary
    CWE-287

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application acer care_center < 4.00.3042 Yes

References