A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.


Security Impact Summary

This vulnerability carries a MEDIUM severity rating with a CVSS v3.1 score of 6.1, indicating it can be exploited remotely over the network with relatively low complexity though user interaction is required and does not require pre-existing privileges . The vulnerability impacts limited data confidentiality, limited integrity, for affected systems. Impacting 60 products from siemens, from siemens, from siemens and 57 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2022, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2022-10-11T11:15:10.997

Last Modified

2024-11-21T07:21:44.787

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 6.1 (MEDIUM)

Weaknesses
  • Type: Secondary
    CWE-79

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System siemens scalance_x200-4p_irt_firmware < 5.5.0 Yes
Hardware siemens scalance_x200-4p_irt - No
Operating System siemens scalance_x201-3p_irt_firmware < 5.5.0 Yes
Hardware siemens scalance_x201-3p_irt - No
Operating System siemens scalance_x201-3p_irt_pro_firmware < 5.5.0 Yes
Hardware siemens scalance_x201-3p_irt_pro - No
Operating System siemens scalance_x202-2irt_firmware < 5.5.0 Yes
Hardware siemens scalance_x202-2irt - No
Operating System siemens scalance_x202-2p_irt_firmware < 5.5.0 Yes
Hardware siemens scalance_x202-2p_irt - No
Operating System siemens scalance_x202-2p_irt_pro_firmware < 5.5.0 Yes
Hardware siemens scalance_x202-2p_irt_pro - No
Operating System siemens scalance_x204-2_firmware < 5.2.5 Yes
Hardware siemens scalance_x204-2 - No
Operating System siemens scalance_x204-2fm_firmware < 5.2.5 Yes
Hardware siemens scalance_x204-2fm - No
Operating System siemens scalance_x204-2ld_firmware < 5.2.5 Yes
Hardware siemens scalance_x204-2ld - No
Operating System siemens scalance_x204-2ld_ts_firmware < 5.2.5 Yes
Hardware siemens scalance_x204-2ld_ts - No
Operating System siemens scalance_x204-2ts_firmware < 5.2.5 Yes
Hardware siemens scalance_x204-2ts - No
Operating System siemens scalance_x204irt_firmware < 5.5.0 Yes
Hardware siemens scalance_x204irt - No
Operating System siemens scalance_x204irt_pro_firmware < 5.5.0 Yes
Hardware siemens scalance_x204irt_pro - No
Operating System siemens scalance_x206-1_firmware < 5.2.5 Yes
Hardware siemens scalance_x206-1 - No
Operating System siemens scalance_x206-1ld_firmware < 5.2.5 Yes
Hardware siemens scalance_x206-1ld - No
Operating System siemens scalance_x208_firmware < 5.2.5 Yes
Hardware siemens scalance_x208 - No
Operating System siemens scalance_x208pro_firmware < 5.2.5 Yes
Hardware siemens scalance_x208pro - No
Operating System siemens scalance_x212-2_firmware < 5.2.5 Yes
Hardware siemens scalance_x212-2 - No
Operating System siemens scalance_x212-2ld_firmware < 5.2.5 Yes
Hardware siemens scalance_x212-2ld - No
Operating System siemens scalance_x216_firmware < 5.2.5 Yes
Hardware siemens scalance_x216 - No
Operating System siemens scalance_x224_firmware < 5.2.5 Yes
Hardware siemens scalance_x224 - No
Operating System siemens scalance_xf201-3p_irt_firmware < 5.5.0 Yes
Hardware siemens scalance_xf201-3p_irt - No
Operating System siemens scalance_xf202-2p_irt_firmware < 5.5.0 Yes
Hardware siemens scalance_xf202-2p_irt - No
Operating System siemens scalance_xf204_firmware < 5.2.5 Yes
Hardware siemens scalance_xf204 - No
Operating System siemens scalance_xf204-2_firmware < 5.2.5 Yes
Hardware siemens scalance_xf204-2 - No
Operating System siemens scalance_xf204-2ba_irt_firmware < 5.5.0 Yes
Hardware siemens scalance_xf204-2ba_irt - No
Operating System siemens scalance_xf204irt_firmware < 5.5.0 Yes
Hardware siemens scalance_xf204irt - No
Operating System siemens scalance_xf206-1_firmware < 5.2.5 Yes
Hardware siemens scalance_xf206-1 - No
Operating System siemens scalance_xf208_firmware < 5.2.5 Yes
Hardware siemens scalance_xf208 - No
Operating System siemens siplus_net_scalance_x202-2p_irt_firmware < 5.5.0 Yes
Hardware siemens siplus_net_scalance_x202-2p_irt - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For siemens's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.