The Synthetic Monitoring Agent for Grafana's Synthetic Monitoring application provides probe functionality and executes network checks for monitoring remote targets. Users running the Synthetic Monitoring agent prior to version 0.12.0 in their local network are impacted. The authentication token used to communicate with the Synthetic Monitoring API is exposed through a debugging endpoint. This token can be used to retrieve the Synthetic Monitoring checks created by the user and assigned to the agent identified with that token. The Synthetic Monitoring API will reject connections from already-connected agents, so access to the token does not guarantee access to the checks. Version 0.12.0 contains a fix. Users are advised to rotate the agent tokens. After upgrading to version v0.12.0 or later, it's recommended that users of distribution packages review the configuration stored in `/etc/synthetic-monitoring/synthetic-monitoring-agent.conf`, specifically the `API_TOKEN` variable which has been renamed to `SM_AGENT_API_TOKEN`. As a workaround for previous versions, it's recommended that users review the agent settings and set the HTTP listening address in a manner that limits the exposure, for example, localhost or a non-routed network, by using the command line parameter `-listen-address`, e.g. `-listen-address localhost:4050`.
This vulnerability carries a HIGH severity rating with a CVSS v3.1 score of 7.2, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts limited data confidentiality, limited integrity, for affected systems. Impacting 1 product from grafana organizations running these solutions should prioritize assessment and patching.
Reported in 2022, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.
2022-11-30T22:15:10.640
2024-11-21T07:30:13.333
Modified
CVSSv3.1: 7.2 (HIGH)
| Type | Vendor | Product | Version/Range | Vulnerable? |
|---|---|---|---|---|
| Application | grafana | synthetic_monitoring_agent | < 0.12.0 | Yes |
SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For grafana's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.