A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps. By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.
This vulnerability carries a MEDIUM severity rating with a CVSS v3.1 score of 6.6, indicating it can be exploited remotely over the network but requires specific conditions to be met without requiring user interaction . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 4 products from siemens, from siemens, from siemens and 1 other, organizations running these solutions should prioritize assessment and patching.
Reported in 2024, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.
2024-01-09T10:15:15.320
2026-06-17T06:24:31.883
Modified
CVSSv3.1: 6.6 (MEDIUM)
| Type | Vendor | Product | Version/Range | Vulnerable? |
|---|---|---|---|---|
| Operating System | siemens | sicam_a8000_cp-8050_firmware | < 05.20 | Yes |
| Hardware | siemens | sicam_a8000_cp-8050 | - | No |
| Operating System | siemens | sicam_a8000_cp-8031_firmware | < 05.20 | Yes |
| Hardware | siemens | sicam_a8000_cp-8031 | - | No |
SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For siemens's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.