Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2025-29931


A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.


Security Impact Summary

This vulnerability carries a LOW severity rating with a CVSS v3.1 score of 3.7, indicating it can be exploited remotely over the network but requires specific conditions to be met without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts and limited availability for affected systems. Impacting 1 product from siemens organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2025, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2025-04-17T11:15:47.807

Last Modified

2025-08-19T14:48:34.130

Status

Analyzed

Source

[email protected]

Severity

CVSSv3.1: 3.7 (LOW)

Weaknesses
  • Type: Secondary
    CWE-130

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application siemens telecontrol_server_basic < 3.1.2.2 Yes

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For siemens's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.