CVE-2025-7090


A vulnerability, which was classified as critical, has been found in Belkin F9K1122 1.00.33. Affected by this issue is the function formConnectionSetting of the file /goform/formConnectionSetting of the component webs. The manipulation of the argument max_Conn/timeOut leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.


Published

2025-07-06T19:15:24.693

Last Modified

2025-07-09T17:25:50.907

Status

Analyzed

Source

[email protected]

Severity

CVSSv3.1: 8.8 (HIGH)

CVSSv2 Vector

AV:N/AC:L/Au:S/C:C/I:C/A:C

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: SINGLE
  • Confidentiality Impact: COMPLETE
  • Integrity Impact: COMPLETE
  • Availability Impact: COMPLETE
Exploitability Score

8.0

Impact Score

10.0

Weaknesses
  • Type: Secondary
    CWE-119
    CWE-121

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Operating System belkin f9k1122_firmware 1.00.33 Yes
Hardware belkin f9k1122 - No

References