A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
2022-04-13T16:15:09.370
2024-11-21T05:50:41.417
Modified
CVSSv3.1: 7.8 (HIGH)
AV:N/AC:M/Au:N/C:C/I:C/A:C
8.6
10.0
Type | Vendor | Product | Version/Range | Vulnerable? |
---|---|---|---|---|
Application | schneider-electric | ecostruxure_control_expert | < 15.1 | Yes |
Application | schneider-electric | ecostruxure_process_expert | < 2021 | Yes |
Application | schneider-electric | remoteconnect | - | Yes |
Hardware | schneider-electric | scadapack_470 | - | No |
Hardware | schneider-electric | scadapack_474 | - | No |
Hardware | schneider-electric | scadapack_570 | - | No |
Hardware | schneider-electric | scadapack_574 | - | No |
Hardware | schneider-electric | scadapack_575 | - | No |