Vulnerability Monitor

The vendors, products, and vulnerabilities you care about

CVE-2022-26507


A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer


Security Impact Summary

This vulnerability carries a CRITICAL severity rating with a CVSS v3.1 score of 9.8, indicating it can be exploited remotely over the network with relatively low complexity without requiring user interaction and does not require pre-existing privileges . The vulnerability impacts confidentiality (data exposure), integrity (unauthorized modifications), and availability (service disruption) for affected systems. Impacting 9 products from att, from schneider-electric, from schneider-electric and 6 others, organizations running these solutions should prioritize assessment and patching.

Historical Context

Reported in 2022, this vulnerability emerged during an era marked by increased sophistication in supply chain attacks, cloud infrastructure vulnerabilities, and software-as-a-service (SaaS) security challenges. Security practices during this period emphasized zero-trust architectures, container security, and API protection.


Published

2022-04-14T13:15:11.637

Last Modified

2024-11-21T06:54:04.920

Status

Modified

Source

[email protected]

Severity

CVSSv3.1: 9.8 (CRITICAL)

CVSSv2 Vector

AV:N/AC:L/Au:N/C:P/I:P/A:P

  • Access Vector: NETWORK
  • Access Complexity: LOW
  • Authentication: NONE
  • Confidentiality Impact: PARTIAL
  • Integrity Impact: PARTIAL
  • Availability Impact: PARTIAL
Exploitability Score

10.0

Impact Score

6.4

Weaknesses
  • Type: Primary
    CWE-787

Affected Vendors & Products
Type Vendor Product Version/Range Vulnerable?
Application att xmill 0.7 Yes
Application schneider-electric ecostruxure_control_expert < 15.1 Yes
Application schneider-electric ecostruxure_control_expert 15.1 Yes
Application schneider-electric ecostruxure_process_expert < 2021 Yes
Application schneider-electric remoteconnect - Yes
Hardware schneider-electric scadapack_470 - No
Hardware schneider-electric scadapack_474 - No
Hardware schneider-electric scadapack_570 - No
Hardware schneider-electric scadapack_574 - No
Hardware schneider-electric scadapack_575 - No

References

How SecUtils Interprets This CVE

SecUtils normalizes and enriches National Vulnerability Database (NVD) records by standardizing vendor and product identifiers, aggregating vulnerability metadata from both NVD and MITRE sources, and providing structured context for security teams. For att's affected products, we extract Common Platform Enumeration (CPE) data, Common Weakness Enumeration (CWE) classifications, CVSS severity metrics, and reference data to enable rapid vulnerability prioritization and asset correlation. This record contains no exploit code, proof-of-concept instructions, or attack methodologies—only defensive intelligence necessary for patch management, risk assessment, and security operations.